PRO-CLEAN swab test (protein residues) 25/pk

130-130-032900

Call For Price https://ghlinc.odoo.com/web/image/product.template/3394/image_1920?unique=5f79514

    This combination does not exist.


    Availability: backordered
    Shipping time if backordered:: jusqu'à 1 semaine
    In case of backorder:: Only replenished IF YOU ORDER IT

     

    PRO-Clean is a ready-to-use rapid protein residue detection device for testing a surface after cleaning. PRO-Clean will turn from green to purple if protein is present in a sample. The more protein collected, the quicker and darker the color change. PRO-Clean is intended to provide rapid validation of surface hygiene and show due diligence in a HACCP program. PRO-Clean will also detect other reducing substances such as simple sugars, tannin, and ascorbic acid.

     

    Note: PRO-Clean is designed to detect invisible/trace amounts ofresidue. Overloading the swab with physical matter by swabbing a visibly dirty surface will inhibit the reaction and produce inaccurate results.

     

    Devices have an 18-month shelf life. Check expiration date on label. Store at 2 – 25 °C (36 – 77 °F).

     

    Model PRO-100 / PRO-Clean™ Rapid Protein Residue Test
    Sensitivity

    At room temperature (21 to 25°C):

    • Detects 80 μg of protein after 1 minute
    • Detects 50 μg of protein after 5 minutes
    • Detects 20 μg of protein after 10 minutes

    Ignore any color change after 10 minutes

    Color matches

    Color of PRO-Clean solution and time in which color change takes place will indicate protein residue levels in sample. By comparing color of solution against chart on PRO-Clean tube label, an estimate of surface cleanliness can be made. There is no need to continue timing if color changes to purple before 10 minutes.

    • Green = Pass result. Clean, no further action required.
    • Grey = Caution. Small amount of residue present; Re-test, re-rinse, or re-clean, depending on protocol.
    • Purple = Fail result. Re-clean and re-test.
    Quantity per pack 100 swabs / package

     

    Directions:

    1. Allow PRO-Clean to equilibrate to room temperature (21 – 25 °C) before use. Holding swab tube firmly, twist and pull top of swab out of swab tube. Condensation may be visible on inside of swab tube; this is normal. Swab tip is premoistened for maximum sample collection. Thoroughly swab a standard 10 x 10 cm (4 x 4 inches) area for a typical flat surface. For irregular surfaces, ensure swabbing technique remains consistent for each test and swab a large enough area to collect a representative sample.

    Important swabbing technique tips:

    • Do not touch swab or inside of sample device with fingers.
    • Rotate swab while collecting sample to maximize sample collection on swab tip.
    • Apply sufficient pressure to create flex in swab shaft.
    • Swab in a crisscross pattern vertically, horizontally, and in both diagonal directions.


    2. After swabbing, replace swab back in swab tube.


    3. To activate device, hold swab tube firmly and use thumb and forefinger to break Snap-Valve by bending bulb forward and backward. Squeeze bulb twice, expelling all liquid down swab shaft.


    4. Bathe swab bud in liquid by shaking for 5 – 10 seconds.

     

    5. Wait 10 minutes at room temperature for color change. Most color changes take place in less than 60 seconds. After 10 minutes, compare color of reagent against PRO-Clean color chart on tube label and record result. Refer to Interpretation of Results below.

     

    Sanitizer Information:

    Common sanitizers at normal concentrations do not cause interference or false-positives. High concentrations of alkaline sanitizers may cause false-negative results in some cases. Peroxide based disinfectants can cause a false-positive color change reaction. It is best practice to wait appropriate time after sanitizing before testing a surface with PRO-Clean. Sanitation is usually a two-step process involving detergent cleaning and subsequent (optional) disinfection. To ensure best results, collect PRO-Clean sample after detergent and rinsing steps, but prior to any terminal disinfection. Product residues left on a surface after detergent cleaning reduces effectiveness of disinfection. Testing prior to disinfection prevents wasted chemicals and time and ensures optimum test performance in a food safety program. If testing prior to disinfection/sanitization is not possible, observe proper dwell time before using PRO-Clean.


     

    PRO-Clean is a ready-to-use rapid protein residue detection device for testing a surface after cleaning. PRO-Clean will turn from green to purple if protein is present in a sample. The more protein collected, the quicker and darker the color change. PRO-Clean is intended to provide rapid validation of surface hygiene and show due diligence in a HACCP program. PRO-Clean will also detect other reducing substances such as simple sugars, tannin, and ascorbic acid.

     

    Note: PRO-Clean is designed to detect invisible/trace amounts ofresidue. Overloading the swab with physical matter by swabbing a visibly dirty surface will inhibit the reaction and produce inaccurate results.

     

    Devices have an 18-month shelf life. Check expiration date on label. Store at 2 – 25 °C (36 – 77 °F).

     

    Model PRO-100 / PRO-Clean™ Rapid Protein Residue Test
    Sensitivity

    At room temperature (21 to 25°C):

    • Detects 80 μg of protein after 1 minute
    • Detects 50 μg of protein after 5 minutes
    • Detects 20 μg of protein after 10 minutes

    Ignore any color change after 10 minutes

    Color matches

    Color of PRO-Clean solution and time in which color change takes place will indicate protein residue levels in sample. By comparing color of solution against chart on PRO-Clean tube label, an estimate of surface cleanliness can be made. There is no need to continue timing if color changes to purple before 10 minutes.

    • Green = Pass result. Clean, no further action required.
    • Grey = Caution. Small amount of residue present; Re-test, re-rinse, or re-clean, depending on protocol.
    • Purple = Fail result. Re-clean and re-test.
    Quantity per pack 100 swabs / package

     

    Directions:

    1. Allow PRO-Clean to equilibrate to room temperature (21 – 25 °C) before use. Holding swab tube firmly, twist and pull top of swab out of swab tube. Condensation may be visible on inside of swab tube; this is normal. Swab tip is premoistened for maximum sample collection. Thoroughly swab a standard 10 x 10 cm (4 x 4 inches) area for a typical flat surface. For irregular surfaces, ensure swabbing technique remains consistent for each test and swab a large enough area to collect a representative sample.

    Important swabbing technique tips:

    • Do not touch swab or inside of sample device with fingers.
    • Rotate swab while collecting sample to maximize sample collection on swab tip.
    • Apply sufficient pressure to create flex in swab shaft.
    • Swab in a crisscross pattern vertically, horizontally, and in both diagonal directions.


    2. After swabbing, replace swab back in swab tube.


    3. To activate device, hold swab tube firmly and use thumb and forefinger to break Snap-Valve by bending bulb forward and backward. Squeeze bulb twice, expelling all liquid down swab shaft.


    4. Bathe swab bud in liquid by shaking for 5 – 10 seconds.

     

    5. Wait 10 minutes at room temperature for color change. Most color changes take place in less than 60 seconds. After 10 minutes, compare color of reagent against PRO-Clean color chart on tube label and record result. Refer to Interpretation of Results below.

     

    Sanitizer Information:

    Common sanitizers at normal concentrations do not cause interference or false-positives. High concentrations of alkaline sanitizers may cause false-negative results in some cases. Peroxide based disinfectants can cause a false-positive color change reaction. It is best practice to wait appropriate time after sanitizing before testing a surface with PRO-Clean. Sanitation is usually a two-step process involving detergent cleaning and subsequent (optional) disinfection. To ensure best results, collect PRO-Clean sample after detergent and rinsing steps, but prior to any terminal disinfection. Product residues left on a surface after detergent cleaning reduces effectiveness of disinfection. Testing prior to disinfection prevents wasted chemicals and time and ensures optimum test performance in a food safety program. If testing prior to disinfection/sanitization is not possible, observe proper dwell time before using PRO-Clean.

    Order-driven inventory

    Submit a Ticket

    Accessories:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.

    People who buy this product also buy:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.

    Recently viewed products:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.