Baker wet and dry bulb hygrometer model B6030

160-110-041000

https://ghlinc.odoo.com/web/image/product.template/3907/image_1920?unique=210d7df

50.33 $ CAD 50.33 CAD 50.33 $ CAD

50.33 $ CAD

    This combination does not exist.


    Availability: in stock
    Shipping time if backordered:: jusqu'à 2 semaines
    In case of backorder:: Usually kept in stock, will be available soon

     

    Professional humidity/dry bulb hygrometer model, mercury-free.

    • Water container screwed to the housing;
    • Very good accuracy,
    • Instructions included, psychrometric chart included allowing the evaluation of the humidity according to the temperature differential of dry and wet bulbs.

     

    Model 
    B6030 
    Range
    -15 to 50°C

     

     

    Thermometer Hygrometer method of use: 

     

    Fill the reservoir and ensure the wick is wet. Note the Dry Bulb reading (left hand column). Subtract the Wet Bulb reading from the Dry Bulb reading to find the Wet Bulb depression. Then use the table (psychrometric chart) on the back of the hygrometer box. Note the difference along the top line. Follow this column down until level with the dry Bulb reading for the Percentage Humidity. Best results will be achieved when the instrument is sited in slightly moving air (approx. 1 to 1.5 meter/second).


     

    Professional humidity/dry bulb hygrometer model, mercury-free.

    • Water container screwed to the housing;
    • Very good accuracy,
    • Instructions included, psychrometric chart included allowing the evaluation of the humidity according to the temperature differential of dry and wet bulbs.

     

    Model 
    B6030 
    Range
    -15 to 50°C

     

     

    Thermometer Hygrometer method of use: 

     

    Fill the reservoir and ensure the wick is wet. Note the Dry Bulb reading (left hand column). Subtract the Wet Bulb reading from the Dry Bulb reading to find the Wet Bulb depression. Then use the table (psychrometric chart) on the back of the hygrometer box. Note the difference along the top line. Follow this column down until level with the dry Bulb reading for the Percentage Humidity. Best results will be achieved when the instrument is sited in slightly moving air (approx. 1 to 1.5 meter/second).

    Control Stand-alone
    Sensor Type Air humidity
    Inventory stocked

    Submit a Ticket

    Accessories:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.

    People who buy this product also buy:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.

    Recently viewed products:

    Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.